Please use this identifier to cite or link to this item: https://hdl.handle.net/10321/2076
DC FieldValueLanguage
dc.contributor.advisorRoss, Ashley Hilton Adrian-
dc.contributor.authorCason, Angelaen_US
dc.date.accessioned2017-01-31T06:48:33Z
dc.date.available2017-01-31T06:48:33Z
dc.date.issued2002-
dc.identifier.otherDIT97951-
dc.identifier.urihttp://hdl.handle.net/10321/2076-
dc.descriptionDissertation submitted in partial compliance with the requirements for the Master's Degree in Technology: Homoeopathy, Durban Institute of Technology, Durban, South Africa, 2002.en_US
dc.description.abstractThe purpose of this study was to investigate whether frequency strength is a parameter requiring consideration when conducting NMR spectroscopy studies on hornoeopathic potencies. To this end, samples of Sulphur 30CH and a Lactose control were analysed using NMR spectrometers operating at three different frequency strengths of 80MHz, 200.MHz and 500.MHz. It was hypothesized that differences existed in the spectra of respective Sulphur samples, control samples, and between parallel samples of Sulphur and control. It was further hypothesized that differences between parallel samples of Sulphur and control would be more noticeable at the lower frequencies. This hypothesis was based on the assumption that a higher frequency strength would have more intense resonance effects on the structure of the homoeopathic potency, thereby disturbing the micro-structural changes induced during potentisation. The design of the investigation was that of a scientific experiment. Potencies of Sulphur and a lactose-based control were prepared to a 30CH potency each, in 87% ethanol. The final prepared volumes (10ml) of Sulphur and control were blinded by means of colour codes by a third party prior to analysis. The blinded samples were transported to the University of Natal, Pietermaritzburg, where they were subjected to analysis using the following instruments: 1) A Varian FT80A 80.MHz instrument 2) A Varian Gemini 200MHz instrument 3) A Varian Inova 500.MHz instrument At each instrument NMR spectroscopy was conducted on ten (10) samples from each group (Sulphur and control). The samples were prepared in coaxial tubes using acetone as both an external lock and reference, and NMR spectra were recorded for each sample. All the samples were run at a thermostatically controlled temperature of 24\xB0C (\xB1 O,2\xB0C), and the laboratory was maintained at a constant temperature of 22\xB0C. The spectra and data of all the samples were recorded in terms of the chemical shift and integration values of their respective CH2, H20 and OH signals.en_US
dc.format.extent116 pen_US
dc.language.isoenen_US
dc.subject.lcshHomeopathyen_US
dc.subject.lcshHomeopathy--Attenuations, dilutions, and potenciesen_US
dc.subject.lcshSulfuren_US
dc.subject.lcshNuclear magnetic resonance spectroscopyen_US
dc.titleA comparison of the 80MHz, 200MHz and 500MHz nuclear magnetic resonance spectra of homoeopathic sulphur 30CHen_US
dc.typeThesisen_US
dc.description.levelMen_US
dc.identifier.doihttps://doi.org/10.51415/10321/2076-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeThesis-
item.languageiso639-1en-
Appears in Collections:Theses and dissertations (Health Sciences)
Files in This Item:
File Description SizeFormat
Cason_2002.pdf8.12 MBAdobe PDFThumbnail
View/Open
Show simple item record

Page view(s)

520
checked on Dec 22, 2024

Download(s)

277
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.