Please use this identifier to cite or link to this item:
https://hdl.handle.net/10321/2615
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Alfa, Dorcas | en_US |
dc.contributor.author | Rathilal, Sudesh | en_US |
dc.contributor.author | Pikwa, Kumnandi | en_US |
dc.contributor.author | Chollom, Martha Noro | en_US |
dc.contributor.author | Pillay, Visvanathan Lingamurti | en_US |
dc.date.accessioned | 2017-10-27T07:24:32Z | |
dc.date.available | 2017-10-27T07:24:32Z | |
dc.date.issued | 2016-07-08 | - |
dc.identifier.citation | Dorcas, A. et al. Development and evaluation of a small scale water disinfection system. Journal of Water, Sanitation and Hygiene for development. Vol 7(3) | en_US |
dc.identifier.uri | http://hdl.handle.net/10321/2615 | - |
dc.description.abstract | Provision of microbiologically safe drinking water for people living in the rural areas of developing countries remains a major challenge to date. A simple gravity-driven membrane point of use system was developed based on woven fabric microfiltration (WFMF) membranes. The WFMF is a loose type of membrane (0.45 μm). However, complete disinfection is not achieved with the WFMF, hence it was incorporated with two disinfectants. This study aimed to combine the WFMF with two disinfectants (Water guard and bromochlor tablets) to bring the water to the accepted quality for drinking. Four different types of water were sourced, considering two factors; E. coli and turbidity content. The WFMF demonstrated excellent filtration performance by producing permeates with turbidity less than 1 NTU for feed turbidity ranging between 10 and 200 NTU. There was 95–99.8% E. coli removal for raw feeds with influent E. coli ranging between 500 and 44,500 CFU/100 mL. Total disinfection was achieved with both disinfectants, however, the effectiveness of the chemical disinfectants in E. coli removal was affected by the quality of water to be disinfected. The study showed that turbidity plays a major role in disinfection performances by increasing chlorine demand on water sources with high turbidity levels. | en_US |
dc.language.iso | en | en_US |
dc.publisher | IWA Publishing | en_US |
dc.title | Development and evaluation of a small scale water disinfection system | en_US |
dc.type | Article | en_US |
dc.publisher.uri | http://washdev.iwaponline.com/content/early/2016/07/08/washdev.2016.093 | en_US |
dc.description.availability | Copyright: 2016. IWA Publishing. Due to copyright restrictions, only the abstract is available. For access to the full text item, please consult the publisher's website. The definitive version of the work is published in Journal of Water Sanitation and Hygiene for Development, Vol 7, Issue 3. DOI: 10.2166/washdev.2016.093 | en_US |
dc.identifier.doi | 10.2166/washdev.2016.093 | - |
local.sdg | SDG06 | - |
item.grantfulltext | none | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
Appears in Collections: | Research Publications (Engineering and Built Environment) |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.