Please use this identifier to cite or link to this item: https://hdl.handle.net/10321/1735
DC FieldValueLanguage
dc.contributor.advisorAdam, Jamila Khatoon-
dc.contributor.advisorMohapi, M.J.-
dc.contributor.authorPillay, Krishnanen_US
dc.date.accessioned2016-11-10T08:56:28Z-
dc.date.available2016-11-10T08:56:28Z-
dc.date.issued2016-
dc.identifier.other663010-
dc.identifier.urihttp://hdl.handle.net/10321/1735-
dc.descriptionSubmitted in fulfillment for the degree of Master of Technology, Clinical Technology: Cardiovascular Perfusion, Durban University of Technology, Durban, South Africa, 2016.en_US
dc.description.abstractIntroduction: A large volume of residual haemodilute blood remains in the cardiopulmonary bypass (CPB) circuit after termination of the bypass. It is common practice in many centres to process residual pump blood with an autologus cell salvage system (ACSS), thereby producing a re-suspended red blood cell (RBC) concentrate and attenuating the need for donor blood RBC concentrate. It has also become standard practice to wash donor pack red blood cells (PRBC) before adding it to neonate cardiopulmonary circuits (Swindell et al., 2007). Manufactures of ACSS recommend 0.9% sodium chloride (NaCl) as a wash solution for processing salvaged blood. Previous studies have demonstrated that washing PRBC with normal saline results in acid-base (Huber et al., 2013) and electrolyte derangements (Varghese et al., 2007). Infusion of normal saline in healthy volunteers also results in significant changes in osmolality (Williams et al., 1999). The use of normal saline as a wash solution in processing residual CPB blood requires investigation. Aims and Objectives: This was a prospective, quantitative in vitro investigation to analyze and compare the quality of residual pump blood post CPB that had been washed with either an unbalanced electrolyte solution (0.9% normal saline) or a balanced electrolyte solution (Balsol®). Both are crystalloid solutions. The primary objective of the present study was to measure and compare the pH, electrolytes, metabolites, osmolality and strong ion difference (SID) of residual pump blood to the pH, electrolytes, metabolites, osmolality and SID of processed cell saver blood, which was washed with either 0.9% normal saline or Balsol® solution. The secondary objective was to measure and compare protein levels (albumin and total protein) in residual pump blood to protein levels in processed cell saver blood, that is washed with either 0.9% normal saline or Balsol® solution. The final objective was to determine the volume, haematocrit and haemoglobin yield post cell saver processing, from the input volume of residual pump blood when washed with either 0.9% normal saline or Balsol® solution. This was the first study of this nature done in the South African population group. Methodology: In this investigation in a series of forty patients (n=40) undergoing elective cardiac surgery with CPB, the first twenty patients were allocated to the NaCl control group (n=20) and the second twenty patients were allocated to the Balsol® interventional group (n=20). The extracorporeal circuit consisted of a standard integral hollow fibre membrane oxygenator and tubing that was primed with 1500-1800 millilitres of balanced crystalloid solution (Balsol®), for both the control group and the interventional group, and addition of 5000 iu heparin. The balanced crystalloid solution (Balsol®) is the approved standard CPB priming solution for all cardiac procedures at Inkosi Albert Luthuli Central Hospital. This setup was used with the Stockert S5 roller pump heart lung machine. The operations were performed as per protocol with standard non-pulsatile CPB and hypothermia was maintained at 28 – 32 ºC (core) and haemodilution (haematocrit 20 % to 30 %). A standard flow rate of 2.4 L/min/m² was used. Cardio protection consisted of either cold Blood Cardioplegia using the Buckberg 4:1 ratio, being four parts blood to one part cardioplegia (with the 35ml of 20 % Dextrose + 1 gram Magnesium Sulphate added per 500ml), or 20ml/kg cold St Thomas II cardioplegia (with addition of 10ml of 8.5% NaHCO3 + 100mg lignocain per litre). Topical cooling was achieved with ice cold 0.9 % saline. Maintenance fluid used during CPB was Balsol® for both the control and the interventional groups. Calcium, potassium and sodium bicarbonate was administered as required during CPB to correct deficits for both groups. Weaning of CPB was performed after re-warming to a rectal temperature of at least 35 ºC for both study groups. Immediately on termination of CPB a blood sample was taken from the sampling manifold of the CPB circuit for pre wash analysis. Residual pump blood was then flushed out with one litre of Balsol® solution for both groups and collected into the Medtronic autolog cell saver reservoir to be processed. In the control study group 0.9% NaCl was used as the wash solution and in the interventional study group Balsol® solution was used as the wash solution. After processing of the salvaged blood is complete, a blood sample was taken for post wash analysis. Clinical data recorded for pre and post wash samples included: pH, pCO2, pO2, [K+], [Na+], [Cl-], [Ca2+], lactate, glucose, [HCO3-], TCO2, haematocrit, haemoglobin (GEM 4000® premier™ blood gas analyser) blood volume (Medtronic autolog) and SID (calculated as per equation). Inorganic phosphate, total magnesium, albumin, total protein (Siemens Advia 1800 blood gas analyser) and osmolality (Gonotech osmometer) were also measured. Results: There was a highly significant decrease (p < 0.05) within the NaCl group after washing with pCO2 (28.3 ± 2.9 vs. <6.0 ± 0.0), [K+] (4.5 ± 0.5 vs. 1.0 ± 0.7), total magnesium (1.7 ± 0.7 vs. 0.29 ± 0), ionized calcium (1.0 ± 0.09 vs. 0.1 ± 0.03), inorganic phosphate (0.9 ± 0.4 vs. 0.09 ± 0.04) and SID (27.1 ± 2.1 vs. 18.4 ± 2.2). There was a highly significant increase (p < 0.05) within the NaCl group after washing with pH (7.5 ± 0.1 vs. 7.7 ± 0.1), [Na+] (132.9 ± 3.2 vs. 146.3 ± 1.9), [Cl-] (107.8 ± 3.1 vs. 127.4 ± 2.1) and osmolaltity (256.9 ± 38.4 vs. 296.2 ± 57.5). There were highly significant decrease (p < 0.05) within the Balsol® group after washing with pCO2 (30.15 ± 6.0 vs. 18.9 ± 4.9), [Na+] (134.7 ± 2.2 vs. 125.6 ± 1), [Cl-] (108.8 ± 2.7 vs. 100.2 ± 1.4), ionized calcium (0.9 ± 0.1 vs. 0.02 ± 0.04), inorganic phosphate (0.8 ± 0.2 vs. 0.1 ± 0.024) and osmolality (288.8 ± 20.6 vs. 272.8 ± 19.9). There were highly significant increase (p < 0.05) within the Balsol® group after washing with pH (7.5 ± 0.1 vs. 7.7 ± 0.1), [K+] (4.2 ± 0.4 vs 4.6 ± 0.3). Total magnesium and SID were similar after washing within the Balsol® group. Albumin and total protein revealed similar significant decreases within both groups after washing. There was a highly significant difference (p < 0.05) in the change between groups after washing in all the variables measured, except for pH, inorganic phosphate, lactate, glucose, albumin, total protein, haematocrit, haemoglobin, and blood volume. Total carbon dioxide and [HCO3-] were not compared because they were incalculable by blood gas analyser in the NaCl group. Conclusion: This investigation concluded that the balanced electrolyte solution Balsol® used for washing residual CPB blood results in a re-suspended RBC concentrate, with an osmolality and electrolyte profile that is superior compared to washing residual CPB blood with 0.9% NaCl solution.en_US
dc.format.extent137 pen_US
dc.language.isoenen_US
dc.subjectCardiopulmonary bypassen_US
dc.subjectResidual pump blooden_US
dc.subjectAutologous cell salvage systemen_US
dc.subjectUnbalanced electrolyte solutionen_US
dc.subjectBalanced electrolyte solutionen_US
dc.subject.lcshElectrolyte solutionsen_US
dc.subject.lcshHeart--Surgeryen_US
dc.subject.lcshBlood--Circulation, Artificialen_US
dc.titleComparative in vitro analysis of a balanced electrolyte solution versus an unbalanced electrolyte solution, for processing of residual pump blood using cell saver for patients undergoing elective cardiac surgeryen_US
dc.typeThesisen_US
dc.description.levelMen_US
dc.identifier.doihttps://doi.org/10.51415/10321/1735-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.openairetypeThesis-
item.cerifentitytypePublications-
Appears in Collections:Theses and dissertations (Health Sciences)
Files in This Item:
File Description SizeFormat
PILLAY_2016_Redacted.pdf4.92 MBAdobe PDFThumbnail
View/Open
Show simple item record

Page view(s)

829
checked on Dec 22, 2024

Download(s) 50

1,143
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.