dc.identifier.citationRathilal, S., Carsky, M., Heyberger, A., and M. Rouskova. 2013. Difference of hydrodynamics for a VPE with and without mass transfer and effect of agitation level on extent of mass transfer. South African Journal of Chemical Engineering. 18(2): pp. 29-39en_US
dc.identifier.issn1026-9185-
dc.identifier.urihttp://hdl.handle.net/10321/1084-
dc.description.abstractLiquid-liquid extraction offers an alternative separation technique, other than distillation, that uses a solvent for the separation of liquid constituents (Pratt, 1983). The vibrating plate extractor (VPE) is a mechanically agitated column that offers many advantages to conventional extraction equipment. Besides the dimensions of the column (diameter and height) and plate design, the VPE has many variables that may be appropriately adjusted to achieve the desired results viz. amplitude and frequency of vibrations, tray spacing, individual flow rates and the final throughput. The first part of the paper investigates the difference in hydrodynamics of the column due to the mass transfer process showing that the hydrodynamics (dispersed phase holdup, droplet size and size distribution) cannot be investigated without mass transfer in order to predict the behaviour during mass transfer. The second part of this paper is devoted to the investigation of the effect of agitation level on the extent of mass transfer.en_US
dc.format.extent11 pen_US
dc.language.isoenen_US
dc.publisherThe South African Journal of Chemical Engineers (SAJChE)en_US
dc.relation.ispartofSouth African journal of chemical engineering-
dc.subjectVibrating plate extractoren_US
dc.subjectVPEen_US
dc.subjectLibrating plate extractoren_US
dc.subjectHydrodynamics mass transferen_US
dc.titleDifference of hydrodynamics for a VPE with and without mass transfer and effect of agitation level on extent of mass transferen_US
dc.typeArticleen_US
dc.publisher.urihttp://www.saiche.co.za/Articleitem.asp?id=37en_US
dc.dut-rims.pubnumDUT-003713en_US
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.languageiso639-1en-
Appears in Collections:Research Publications (Engineering and Built Environment)
Files in This Item:
File Description SizeFormat
rathilal_et_al_2013_output_sajce.pdf709.39 kBAdobe PDFThumbnail
View/Open
Show simple item record

Page view(s) 50

831
checked on Dec 22, 2024

Download(s) 50

430
checked on Dec 22, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.